Bioelectrical impedance analysis measures the opposition of body tissues to a low‑level alternating current. By injecting a safe, sinusoidal signal through surface electrodes and measuring the
Inquire NowBioelectrical impedance analysis measures the opposition of body tissues to a low‑level alternating current. By injecting a safe, sinusoidal signal through surface electrodes and measuring the resulting voltage drop, the device determines the body's impedance vector, which separates into resistance and reactance components.
Typical wholesale BIA units operate at multiple frequencies ranging from 5 kHz to 500 kHz. Low frequencies preferentially penetrate extracellular fluid, while higher frequencies penetrate intracellular spaces, enabling segmental analysis of water distribution.
The instrument reports raw impedance (Z), resistance (R), and reactance (Xc) at each frequency. From these values, proprietary algorithms estimate total body water, extracellular water, intracellular water, fat‑free mass, and body fat percentage using empirically derived equations validated against reference methods such as DXA.
| Parameter | Typical Value / Range |
|---|---|
| Measurement Frequencies | 5 kHz, 50 kHz, 100 kHz, 200 kHz, 500 kHz (configurable) |
| Impedance Measurement Range | 100 Ω – 1 kΩ (typical human range) |
| Accuracy (Resistance) | ±1 % of reading ±0.5 Ω |
| Electrode Type | Disposable Ag/AgCl snap‑on or reusable stainless steel |
| Display | 7‑inch touchscreen LCD, 800×480 px |
| Data Output | USB host, Ethernet, optional Wi‑Fi; CSV, JSON, HL7 formats |
| Power Supply | 100‑240 V AC, 50/60 Hz, 30 W max |
| Operating Temperature | 10 °C – 40 °C, 10 % – 90 % RH non‑condensing |
| Dimensions (W×D×H) | 320 mm × 260 mm × 120 mm |
Before shipment each unit undergoes a two‑point calibration using precision resistors traceable to national standards. In‑field verification can be performed with a supplied phantom load that simulates a 500 Ω resistive impedance, allowing users to confirm measurement drift within the specified tolerance.
Wholesale BIA equipment is selected by organizations that require repeatable, non‑invasive body composition data for large cohorts. The ability to acquire measurements in under 30 seconds per subject supports high‑throughput screening while maintaining clinical relevance.
OEM buyers can specify electrode cable length, connector type (M8, DIN, or proprietary), and enclosure color to match facility branding. Software options include local data storage, remote database synchronization via HL7, and multilingual user interfaces (English, Spanish, Mandarin).
To receive a detailed quotation or request a sample unit, please contact our sales team via the inquiry form.