
This device measures subcutaneous adipose tissue thickness using pulsed ultrasound waves, providing a non‑invasive estimate of body fat percentage based on echo‑time delay and tissue acoustic
Inquire NowThis device measures subcutaneous adipose tissue thickness using pulsed ultrasound waves, providing a non‑invasive estimate of body fat percentage based on echo‑time delay and tissue acoustic impedance.
| Parameter | Typical Value | Unit |
|---|---|---|
| Ultrasound Frequency | 5 | MHz |
| Measurement Depth Range | 0–50 | mm |
| Resolution | 0.1 | mm |
| Repeatability (SD) | ±0.5 | mm |
| Power Consumption | <0.5 | W |
| Operating Temperature | 0–40 | °C |

In corporate wellness programs, the analyzer provides objective baseline data for tracking employee health interventions, allowing safety officers to correlate body‑fat trends with incident rates. Fitness equipment manufacturers embed the sensor into treadmill consoles to offer users real‑time feedback, enhancing product differentiation without requiring invasive calipers. Nutritional supplement firms use the device in clinical trials to validate claims about fat‑loss efficacy, delivering repeatable measurements that satisfy regulatory bodies seeking quantitative endpoints.
Each unit undergoes a three‑stage verification: first, acoustic pathway integrity is tested with a reference phantom of known attenuation; second, electronic noise floor is measured under shielded conditions to confirm signal‑to‑noise ratio exceeds 40 dB; third, firmware checksum validation guarantees that measurement algorithms remain unchanged from the approved version. Calibration traceability to NIST‑standard ultrasound spectrometers is maintained, and a calibration certificate is shipped with every order.
| Option | Description | Impact on Lead Time |
|---|---|---|
| Probe Cable Length | 0.5 m, 1 m, 2 m polyurethane‑jacketed | No change |
| Housing Color | Standard gray, safety yellow, corporate palette (Pantone) | +3 days |
| Software Suite | Basic viewer, advanced analytics API, HL7 interface | +5 days |
| Calibration Interval | 6 months, 12 months, on‑site verification kit | No change |
Yes, the gain and frequency settings can be programmed via the device menu to optimize penetration for thinner subcutaneous layers (pediatric) or thicker layers (adult athletes) without hardware changes.
Please provide the intended application site (e.g., clinic, gym, industrial site), expected daily measurement volume, any required software interfaces, and preferred probe cable length.
Each unit receives a functional test using a multi‑layer tissue‑equivalent phantom, a visual inspection of housing and connectors, and a firmware integrity check. A QC passport documenting these results is included in the packaging.
To discuss configuration options, lead times, or request a sample unit, use the link below to reach our technical sales team.
Request Quote