This device captures full‑body surface geometry using a sweeping laser line and high‑resolution CMOS sensors. The system operates at a Class M laser safety level, allowing prolonged exposure without
Inquire NowThis device captures full‑body surface geometry using a sweeping laser line and high‑resolution CMOS sensors. The system operates at a Class M laser safety level, allowing prolonged exposure without additional eye protection.
A single laser diode emits a narrow line that is swept vertically across the subject by a galvanometer mirror. Two offset cameras capture the laser strip from different angles, enabling triangulation for each point.
The scanner records X, Y, Z coordinates at a density of up to 0.5 mm point spacing, producing a dense point cloud that is later meshed into a watertight STL model.
Synchronization between the mirror position and camera frames is handled by an FPGA, ensuring sub‑millisecond timing jitter.
| Parameter | Value / Range |
|---|---|
| Scanning Volume | 2000 mm × 1000 mm × 600 mm (W × D × H) |
| Point Spacing (nominal) | 0.3 mm – 0.6 mm adjustable |
| Single‑Shot Accuracy | ±0.2 mm (RMS) over central zone |
| Scan Speed | Full body in 4 seconds (including data transfer) |
| Laser Wavelength | 650 nm (visible red), Class M |
| Power Consumption | 120 VA typical, 150 VA peak |
| Output Formats | PLY, STL, OBJ, PTX, ASCII CSV |
| Operating Temperature | 10 °C – 35 °C (non‑condensing) |

The scanner’s mechanical envelope and software can be adapted to specific project needs without altering the core laser‑triangulation engine.
Each unit undergoes a factory acceptance test using a NIST‑traceable artifacts board with known planar and curved features.
Point‑cloud accuracy is verified by comparing scanned data to a calibrated reference sphere; deviations are logged and compensated in the firmware lookup table.
Laser power and camera gain are stabilized via closed‑loop feedback to maintain performance across the specified temperature range.
A calibration certificate is supplied with every shipment, and field recalibration kits are available for annual verification.